ATHENS NEIGHBOURHOODS: AIR AND HEAT
Patision Avenue: nitrogen dioxide at one and a half times the EU limit
In 2025 the official Patision station measured an average of 62.0 µg/m³ of nitrogen dioxide (NO2), more than one and a half times the EU limit (40 micrograms per cubic metre). The low-cost sensors that the City of Athens runs in its squares suggest that the pollution is not confined to one street: their highest readings are around Omonia.
- Official stations: Piraeus-1 (57.3) and Aristotelous (42.8) were also over the limit: 3 of the 12 stations in Attica with complete data for 2025.
- Sensors: of the City’s 97 sensors with enough readings this year, 19 average more than 40 for NO2. The highest are in Kotzia Square (61.6), at Korai and Klafthmonos (56.1) and in Omonia (54.6). These are indicative values, not annual means.
The official stations: few, with Patision on top
The national network has 14 stations in Attica and only four inside the Municipality of Athens. In 2025 two of them, Athinas and Votanikos, did not have enough valid hours for an annual mean. Patision is the most polluted station every year: 69.0 µg/m³ in 2022 and 62.0 in 2025. Since 2022, the first year without pandemic lockdowns, NO2 has fallen at 8 of the 10 stations with data for both years; it rose at Piraeus-1 and Liosia.
What the sensors add
The City’s sensors are many and close together: almost a hundred in squares, parks and sports grounds. The three highest are in the 1st Municipal District, around Omonia, followed by squares in Agios Panteleimonas, Kypseli and Petralona.
The only direct comparison we can make puts the sensor below the station. The sensor in Pavlou Bakogianni Square is 190 metres from the Patision station and reads 45.7. But the station stands on the avenue, while the sensor is in the square, has been measuring since March and has not yet been through a winter.
The sensor in your own square is on the Athens neighbourhoods dashboard.
What to keep in mind
- The City’s sensors are low-cost: they show differences between areas and seasons, not readings equivalent to the official network’s.
- The sensor averages cover the days with readings up to 21 October 2026, and each sensor started on a different day. They are not annual means, and the EU limit applies to the annual mean.
- The World Health Organization’s stricter guideline (10 µg/m³) is exceeded by almost all the stations and by every sensor.
- The official data are verified up to 2025. Greece does not send up-to-date data to the European Environment Agency, so the two series do not overlap in time.
Sources: European Environment Agency (verified air quality data), City of Athens (Smart Neighbourhood). Processing: DataForGreece.